94577-4

Laboratory

Maximum clot strength amplitude [Length] in Blood by Thromboelastography.resonance.arachidonate induced

Definition

The maximum clot strength in the presence of arachidonic acid, as measured by the amplitude of resonance of the blood meniscus as the blood sample clots. In this test, thrombin activity is blocked, and arachidonic acid (AA) is used to activate platelets in order to measure the clot strength based on platelet activation by AA, which result is used to determine the relative contribution of AA-induced platelet activation [LOINC: 94579-0] to the overall clot strength [LOINC: 91125-5]. This term was created for, but is not limited in use to, the Submitter's test kit, the TEG6s PlateletMapping ADP & AA Assay Cartridge for heparinized blood.

LOINC 6-Axis Classification

Component

Maximum clot strength amplitude

Property

Len

Time Aspect

Pt

System

Bld

Scale Type

Qn

Method Type

Thromboelastography.resonance.arachidonate induced

Details

Class

COAG

Order/Observation

Observation

Short Name

Maximum clot strength amplitude Bld Thromboelastography.resonance.arachidonate induced

Display Name

Maximum clot strength amplitude (Bld) [Length]

Related Names

BloodCOAGULATIONHematologyHemeLengthPoint in timeQNTQuanQuantQuantitativeRandomRes TEGTEGThrombelastographyThrombelastometryWBWhole blood

Frequently Asked Questions

What is LOINC code 94577-4?

LOINC code 94577-4 identifies "Maximum clot strength amplitude [Length] in Blood by Thromboelastography.resonance.arachidonate induced". The maximum clot strength in the presence of arachidonic acid, as measured by the amplitude of resonance of the blood meniscus as the blood sample clots. In this test, thrombin activity is blocked, and arachidonic acid (AA) is used to activate platelets in order to measure the clot strength based on platelet activation by AA, which result is used to determine the relative contribution of AA-induced platelet activation [LOINC: 94579-0] to the overall clot strength [LOINC: 91125-5]. This term was created for, but is not limited in use to, the Submitter's test kit, the TEG6s PlateletMapping ADP & AA Assay Cartridge for heparinized blood.

What does 94577-4 measure?

This code measures Maximum clot strength amplitude in Bld. It belongs to the COAG class in the LOINC classification.

What is LOINC?

LOINC (Logical Observation Identifiers Names and Codes) is a universal standard for identifying laboratory and clinical observations. It is maintained by the Regenstrief Institute and used worldwide for health data exchange.