AutoICD API

91120-6

Laboratory

Antithrombin in Platelet poor plasma by Chromo.no addition of heparin

Definition

This term represents an antithrombin (AT) assay which, in contrast to typical AT assays, is performed in the ABSENCE of heparin. This assay is also known as "Progressive antithrombin assay." It is used to identify type IIb AT deficiency, which is caused by a mutation in the AT heparin binding site (HBS). In type IIb AT deficiency, AT activity is reduced in the presence of heparin but is normal in the absence of heparin.[PMID: 19141163] This term was created for, but is not limited in use to, the Biophen Antithrombin 5 assay's VARIANT Method, which is performed without heparin. In patients with type IIb AT deficiency, AT activity is expected to be normal in patients with an HBS mutation.

LOINC 6-Axis Classification

Component

Antithrombin

Property

RelCCnc

Time Aspect

Pt

System

PPP

Scale Type

Qn

Method Type

Chromo.no addition of heparin

Details

Class

COAG

Order/Observation

Observation

Short Name

AT III PPP Chromo.no added heparin

Display Name

Antithrombin Chromo.no addition of heparin (PPP) [Rel catalytic activity/Vol]

Related Names

Anti thrombinAntithrmAntithrombin IIIAntithrombnAnti-XaATAT IIIATIIIChromo.no added heparinChromogenic assayCOAGULATIONENZYEnzymatic assayHematologyHemeHeparin cofactor IPlasPlatelet poor plasmaPoint in timeQNTQuanQuantQuantitativeRandomRlCCncThrombin inhibitor I

Frequently Asked Questions

What is LOINC code 91120-6?

LOINC code 91120-6 identifies "Antithrombin in Platelet poor plasma by Chromo.no addition of heparin". This term represents an antithrombin (AT) assay which, in contrast to typical AT assays, is performed in the ABSENCE of heparin. This assay is also known as "Progressive antithrombin assay." It is used to identify type IIb AT deficiency, which is caused by a mutation in the AT heparin binding site (HBS). In type IIb AT deficiency, AT activity is reduced in the presence of heparin but is normal in the absence of heparin.[PMID: 19141163] This term was created for, but is not limited in use to, the Biophen Antithrombin 5 assay's VARIANT Method, which is performed without heparin. In patients with type IIb AT deficiency, AT activity is expected to be normal in patients with an HBS mutation.

What does 91120-6 measure?

This code measures Antithrombin in PPP. It belongs to the COAG class in the LOINC classification.

What is LOINC?

LOINC (Logical Observation Identifiers Names and Codes) is a universal standard for identifying laboratory and clinical observations. It is maintained by the Regenstrief Institute and used worldwide for health data exchange.