89579-7
LaboratoryTroponin I.cardiac [Mass/volume] in Serum or Plasma by High sensitivity method
Definition
The "high sensitivity" troponin assays manufactured by different vendors have different analytical characteristics, including the limit of detection and 99% upper reference limit (URL). The quantitative results from different assays should not be compared to make clinical decisions, and reporting the quantitative result in isolation is not recommended. The troponin high sensitivity quantitative results should be reported with information about the assay and/or the interpretation, depending on the specific reporting method used in a given laboratory or hospital, that are included in the High sensitivity Troponin I [LOINC: 89577-1] and Troponin T [LOINC: 89576-3] panels. 1. The laboratory device 99th percentile upper reference limit [LOINC: 89581-3] 2. The laboratory device coefficient of variation at 99th percentile URL [LOINC: 89580-5] 3. The laboratory device detection limit [LOINC: 87706-8] 4. Interpretation for troponin T [LOINC: 89575-5] and/or troponin I [LOINC: 89578-9] [PMID: 25204966]
LOINC 6-Axis Classification
Component
Troponin I.cardiac
Property
MCnc
Time Aspect
Pt
System
Ser/Plas
Scale Type
Qn
Method Type
High sensitivity
Details
Class
CHEM
Order/Observation
Observation
Short Name
Troponin I SerPl HS-mCnc
Display Name
Troponin I.cardiac High sensitivity method [Mass/Vol]
Related Names
Frequently Asked Questions
What is LOINC code 89579-7?
LOINC code 89579-7 identifies "Troponin I.cardiac [Mass/volume] in Serum or Plasma by High sensitivity method". The "high sensitivity" troponin assays manufactured by different vendors have different analytical characteristics, including the limit of detection and 99% upper reference limit (URL). The quantitative results from different assays should not be compared to make clinical decisions, and reporting the quantitative result in isolation is not recommended. The troponin high sensitivity quantitative results should be reported with information about the assay and/or the interpretation, depending on the specific reporting method used in a given laboratory or hospital, that are included in the High sensitivity Troponin I [LOINC: 89577-1] and Troponin T [LOINC: 89576-3] panels. 1. The laboratory device 99th percentile upper reference limit [LOINC: 89581-3] 2. The laboratory device coefficient of variation at 99th percentile URL [LOINC: 89580-5] 3. The laboratory device detection limit [LOINC: 87706-8] 4. Interpretation for troponin T [LOINC: 89575-5] and/or troponin I [LOINC: 89578-9] [PMID: 25204966]
What does 89579-7 measure?
This code measures Troponin I.cardiac in Ser/Plas. It belongs to the CHEM class in the LOINC classification.
What is LOINC?
LOINC (Logical Observation Identifiers Names and Codes) is a universal standard for identifying laboratory and clinical observations. It is maintained by the Regenstrief Institute and used worldwide for health data exchange.