AutoICD API

89521-9

Laboratory

Ganglioside GM1 IgG Ab [Presence] in Serum by Line blot

Definition

This term was created for, but is not limited in use to, the submitter's test strip, a membrane strip pre-coated with a specific set of antigens in parallel lines. If antibodies to any of those antigens are present in the patient's serum, they will bind to the specific antigen. The bound patient antibodies are then detected using labelled anti-human antibodies. Manufacturers call this method by different names, including immunoblot, line blot, and line immunoassay. LOINC uses the immunoblot (IB) method to mean that some electrophoretic/chromatographic separation occurs such that position (size) of the band is part of the assessment (as in Western blot). Because this assay does not involve a separation step but rather uses strips with pre-fixed antigens, the LOINC Method for this term is Line blot.

LOINC 6-Axis Classification

Component

Ganglioside GM1 Ab.IgG

Property

PrThr

Time Aspect

Pt

System

Ser

Scale Type

Ord

Method Type

Line blot

Details

Class

SERO

Order/Observation

Both

Short Name

GM1 Gangl IgG Ser Ql Line blot

Display Name

Ganglioside GM1 IgG Line blot Ql (S)

Related Names

ABSAbyAntbyAntiAntibodiesAntibodyAutoantibodiesAutoantibodyGanglioside monosialoGM1 GanglImmune globulin GImmunoglobulin GMonosialogangliosideOrdinalPoint in timePRQLQualQualitativeRandomScreenSerologySerumSR

Frequently Asked Questions

What is LOINC code 89521-9?

LOINC code 89521-9 identifies "Ganglioside GM1 IgG Ab [Presence] in Serum by Line blot". This term was created for, but is not limited in use to, the submitter's test strip, a membrane strip pre-coated with a specific set of antigens in parallel lines. If antibodies to any of those antigens are present in the patient's serum, they will bind to the specific antigen. The bound patient antibodies are then detected using labelled anti-human antibodies. Manufacturers call this method by different names, including immunoblot, line blot, and line immunoassay. LOINC uses the immunoblot (IB) method to mean that some electrophoretic/chromatographic separation occurs such that position (size) of the band is part of the assessment (as in Western blot). Because this assay does not involve a separation step but rather uses strips with pre-fixed antigens, the LOINC Method for this term is Line blot.

What does 89521-9 measure?

This code measures Ganglioside GM1 Ab.IgG in Ser. It belongs to the SERO class in the LOINC classification.

What is LOINC?

LOINC (Logical Observation Identifiers Names and Codes) is a universal standard for identifying laboratory and clinical observations. It is maintained by the Regenstrief Institute and used worldwide for health data exchange.