88723-2
LaboratoryAsialoganglioside GM1 IgG+IgM Ab [Units/volume] in Serum by Immunoassay
Definition
After washing off unbound substances, a horseradish-peroxidase (HRP) labeled antibody mix against human IgG and IgM is added to the wells and incubated for another two hours. Following a second washing step in which unbound antibody-enzyme reagent is removed, a substrate solution containing tetramethylbenzidine (TMB) is added to the wells. A blue color develops in proportion to the amount of antiganglioside autoantibodies bound to the microplate in the initial step. Color development is stopped by adding an acidic stop solution (diluted sulfuric acid) which turns the blue solution into yellow. The intensity of the color is measured at 450 nm. The measured absorbance is proportional to the titer of anti-ganglioside antibodies present in a given sample. The titers of anti-ganglioside autoantibodies are expressed as ratios of the calibrator and can be assigned to titer categories. Sample reports are quantitative.
LOINC 6-Axis Classification
Component
Asialoganglioside GM1 Ab.IgG+IgM
Property
ACnc
Time Aspect
Pt
System
Ser
Scale Type
Qn
Method Type
IA
Details
Class
SERO
Order/Observation
Both
Short Name
GM1 Asialo IgG+IgM Ser IA-aCnc
Display Name
Asialoganglioside GM1 IgG+IgM IA Qn (S)
Related Names
Frequently Asked Questions
What is LOINC code 88723-2?
LOINC code 88723-2 identifies "Asialoganglioside GM1 IgG+IgM Ab [Units/volume] in Serum by Immunoassay". After washing off unbound substances, a horseradish-peroxidase (HRP) labeled antibody mix against human IgG and IgM is added to the wells and incubated for another two hours. Following a second washing step in which unbound antibody-enzyme reagent is removed, a substrate solution containing tetramethylbenzidine (TMB) is added to the wells. A blue color develops in proportion to the amount of antiganglioside autoantibodies bound to the microplate in the initial step. Color development is stopped by adding an acidic stop solution (diluted sulfuric acid) which turns the blue solution into yellow. The intensity of the color is measured at 450 nm. The measured absorbance is proportional to the titer of anti-ganglioside antibodies present in a given sample. The titers of anti-ganglioside autoantibodies are expressed as ratios of the calibrator and can be assigned to titer categories. Sample reports are quantitative.
What does 88723-2 measure?
This code measures Asialoganglioside GM1 Ab.IgG+IgM in Ser. It belongs to the SERO class in the LOINC classification.
What is LOINC?
LOINC (Logical Observation Identifiers Names and Codes) is a universal standard for identifying laboratory and clinical observations. It is maintained by the Regenstrief Institute and used worldwide for health data exchange.