AutoICD API

78872-9

Laboratory

OPC3373 (Metabolite of Ariprazole) [Z-score] in Urine

Definition

This term represents the Z-score for a patient's drug result. It was created for, but not limited in use to, the Ameritox Medication Monitoring system, which assesses a patient's medication compliance by comparing the patient's result to a reference database of results from chronic pain patients who were known to be adherent to their medication regimen. In order to compare to the reference database, the patient's result is first normalized based on urine creatinine and lean body mass using a proprietary algorithm, and then the normalized result is converted to a Z-score based on the reference population. If the patient's Z-score is between -2 and +2, the patient is likely to be taking the drug as prescribed. If the score is less than -2, the patient's drug level is lower than expected, which could be a sign that the patient stopped taking the drug or has altered metabolism. If the score is greater than +2, the patient's drug level is higher than expected, which could occur for a number of reasons, including overuse of the drug or impaired metabolism due to liver or kidney disease.

LOINC 6-Axis Classification

Component

OPC3373

Property

Zscore

Time Aspect

Pt

System

Urine

Scale Type

Qn

Method Type

N/A

Details

Class

DRUG/TOX

Order/Observation

Observation

Short Name

OPC3373 Z-score Ur

Display Name

OPC3373 (Metabolite of Ariprazole) (U) [Z-score]

Related Names

Aripiprazole metaboliteDRUG/TOXICOLOGYDrugsPoint in timeQNTQuanQuantQuantitativeRandomStandard scoreUAURUrnZ scoreZ valueZ-score

Frequently Asked Questions

What is LOINC code 78872-9?

LOINC code 78872-9 identifies "OPC3373 (Metabolite of Ariprazole) [Z-score] in Urine". This term represents the Z-score for a patient's drug result. It was created for, but not limited in use to, the Ameritox Medication Monitoring system, which assesses a patient's medication compliance by comparing the patient's result to a reference database of results from chronic pain patients who were known to be adherent to their medication regimen. In order to compare to the reference database, the patient's result is first normalized based on urine creatinine and lean body mass using a proprietary algorithm, and then the normalized result is converted to a Z-score based on the reference population. If the patient's Z-score is between -2 and +2, the patient is likely to be taking the drug as prescribed. If the score is less than -2, the patient's drug level is lower than expected, which could be a sign that the patient stopped taking the drug or has altered metabolism. If the score is greater than +2, the patient's drug level is higher than expected, which could occur for a number of reasons, including overuse of the drug or impaired metabolism due to liver or kidney disease.

What does 78872-9 measure?

This code measures OPC3373 in Urine. It belongs to the DRUG/TOX class in the LOINC classification.

What is LOINC?

LOINC (Logical Observation Identifiers Names and Codes) is a universal standard for identifying laboratory and clinical observations. It is maintained by the Regenstrief Institute and used worldwide for health data exchange.