78747-3
LaboratoryPeritoneal equilibration test panel - Peritoneal dialysis fluid
Definition
This panel contains terms for the Peritoneal Equilibration Test (PET) which is used to assess transport properties of the peritoneal membrane for patients undergoing peritoneal dialysis. Patients arrive at the dialysis unit in the morning with their overnight dwell fluid still in the abdomen. The overnight fluid is drained, and after complete drainage, in the classic PET, 2000 ml of a 2.27% glucose solution is instilled and peritoneal dialysis is begun. Ten ml samples are drawn at time 0, 2, and 4 hours to measure creatinine, urea, and glucose. The PET assesses the rate of solute equilibration between peritoneal capillary blood and dialysate based on the ratio of the solute concentrations in dialysate and plasma (D/P). PET results are used to adjust various aspects of a patient's peritoneal dialysis regimen, including dwell time, number of exchanges, and dialysis volume and composition. [PMID: 7474677]
LOINC 6-Axis Classification
Component
Peritoneal equilibration test panel
Property
-
Time Aspect
Pt
System
Dial fld prt
Scale Type
-
Method Type
N/A
Details
Class
PANEL.CHEM
Order/Observation
Order
Short Name
PET Pnl DiafP
Display Name
Peritoneal equilibration test panel (Perit dial fld)
Related Names
Frequently Asked Questions
What is LOINC code 78747-3?
LOINC code 78747-3 identifies "Peritoneal equilibration test panel - Peritoneal dialysis fluid". This panel contains terms for the Peritoneal Equilibration Test (PET) which is used to assess transport properties of the peritoneal membrane for patients undergoing peritoneal dialysis. Patients arrive at the dialysis unit in the morning with their overnight dwell fluid still in the abdomen. The overnight fluid is drained, and after complete drainage, in the classic PET, 2000 ml of a 2.27% glucose solution is instilled and peritoneal dialysis is begun. Ten ml samples are drawn at time 0, 2, and 4 hours to measure creatinine, urea, and glucose. The PET assesses the rate of solute equilibration between peritoneal capillary blood and dialysate based on the ratio of the solute concentrations in dialysate and plasma (D/P). PET results are used to adjust various aspects of a patient's peritoneal dialysis regimen, including dwell time, number of exchanges, and dialysis volume and composition. [PMID: 7474677]
What does 78747-3 measure?
This code measures Peritoneal equilibration test panel in Dial fld prt. It belongs to the PANEL.CHEM class in the LOINC classification.
What is LOINC?
LOINC (Logical Observation Identifiers Names and Codes) is a universal standard for identifying laboratory and clinical observations. It is maintained by the Regenstrief Institute and used worldwide for health data exchange.