56024-3

Laboratory

Influenza virus A N1 RNA [Units/volume] (viral load) in Specimen by NAA with probe detection

Definition

The values are the number of PCR cycles and are typically reported out as "Ct value" (cycle threshold). If the number of cycles permitted by the procedure are exceeded prior to the threshold being reached, the value is reported out as zero (0). If the threshold is reached prior to the maximum number of cycles, the number of cycles taken to reach the threshold is reported ( e.g. 1-40). A graph representing the threshold and the Ct curve is included: The yellow line is the negative control (never reaches the threshold) and the colored lines are all "positive", reaching the threshold at different number of cycles (i.e. 19.5 to 24.1).

LOINC 6-Axis Classification

Component

Influenza virus A N1 RNA

Property

ACnc

Time Aspect

Pt

System

XXX

Scale Type

Qn

Method Type

Probe.amp.tar

Details

Class

MICRO

Order/Observation

Both

Short Name

FLUAV N1 RNA Spec NAA+probe-aCnc

Display Name

FLUAV N1 RNA NAA+probe Qn (Specimen)

Related Names

3 Self-Sustaining Sequence Replication3SR SRAmplifAmplificationAmplifiedArbitrary concentrationAvian influenzaBird fluDNA NUCLEIC ACID PROBEDNA probeFLUAFLUAVFLUAV N1FLUVFowl plagueIDInfectious DiseaseInfectiousDiseaseInfluInfluenza AInfluenza A virusLATLCRLigase chain reactionLigation-activated transcriptionMicrobiologyMiscMiscellaneousNAA+probeNAATNASBANucleic acid sequence based analysisOtherPCRPoint in timePolymerase chain reactionProbe ampProbe with ampificationProbe with target amplificationQBRQNTQuanQuantQuantitativeRandomRibonucleic acidSDASpecStrand Displacement AmplificationTMATo be specified in another part of the messageTranscription mediated amplificationUnspecifiedViral load

Frequently Asked Questions

What is LOINC code 56024-3?

LOINC code 56024-3 identifies "Influenza virus A N1 RNA [Units/volume] (viral load) in Specimen by NAA with probe detection". The values are the number of PCR cycles and are typically reported out as "Ct value" (cycle threshold). If the number of cycles permitted by the procedure are exceeded prior to the threshold being reached, the value is reported out as zero (0). If the threshold is reached prior to the maximum number of cycles, the number of cycles taken to reach the threshold is reported ( e.g. 1-40). A graph representing the threshold and the Ct curve is included: The yellow line is the negative control (never reaches the threshold) and the colored lines are all "positive", reaching the threshold at different number of cycles (i.e. 19.5 to 24.1).

What does 56024-3 measure?

This code measures Influenza virus A N1 RNA in XXX. It belongs to the MICRO class in the LOINC classification.

What is LOINC?

LOINC (Logical Observation Identifiers Names and Codes) is a universal standard for identifying laboratory and clinical observations. It is maintained by the Regenstrief Institute and used worldwide for health data exchange.