AutoICD API

49010-2

Laboratory

Platelet aggregation [Units/volume] in Platelet rich plasma by ADP induced

Definition

Assay is used to measure platelet P2Y12 receptor blockade known to occur with some drugs including the thienopyridine class of drugs, including clopidogrel (Plavis(r)). VerifyNow P2Y12 Assay from Accumetrics uses adenosine-5-diphosphate(ADP/PGE1) to induce platelet activation. Activated platelets bind fibrinogen in proportion to the number of expressed platelet GPIIb/IIIa receptors. Light transmittance increases as activated platelets bind and aggregate the fibrinogen-coated beads. A turbidimetric based optical detection system measures change in optical signal caused by aggregation and reports results in P2Y12 Reaction Units(PRU). Information from VerifyNow P2Y12 Assay package insert from Accumetrics dated 2006 09 01

LOINC 6-Axis Classification

Component

Platelet aggregation

Property

ACnc

Time Aspect

Pt

System

PRP

Scale Type

Qn

Method Type

Aggregometry.adenosine diphosphate induced

Details

Class

COAG

Order/Observation

Both

Short Name

PA PRP ADP-aCnc

Display Name

Platelet aggregation Qn (PRP)

Related Names

ADPAggAggrANEDArbitrary concentrationCOAGULATIONHematologyHemeMedication stressPAPlPlatelet rich plasmaPlateletsPlateltPltPoint in timeQNTQuanQuantQuantitativeRandomThrombocyteThrombocytes

Frequently Asked Questions

What is LOINC code 49010-2?

LOINC code 49010-2 identifies "Platelet aggregation [Units/volume] in Platelet rich plasma by ADP induced". Assay is used to measure platelet P2Y12 receptor blockade known to occur with some drugs including the thienopyridine class of drugs, including clopidogrel (Plavis(r)). VerifyNow P2Y12 Assay from Accumetrics uses adenosine-5-diphosphate(ADP/PGE1) to induce platelet activation. Activated platelets bind fibrinogen in proportion to the number of expressed platelet GPIIb/IIIa receptors. Light transmittance increases as activated platelets bind and aggregate the fibrinogen-coated beads. A turbidimetric based optical detection system measures change in optical signal caused by aggregation and reports results in P2Y12 Reaction Units(PRU). Information from VerifyNow P2Y12 Assay package insert from Accumetrics dated 2006 09 01

What does 49010-2 measure?

This code measures Platelet aggregation in PRP. It belongs to the COAG class in the LOINC classification.

What is LOINC?

LOINC (Logical Observation Identifiers Names and Codes) is a universal standard for identifying laboratory and clinical observations. It is maintained by the Regenstrief Institute and used worldwide for health data exchange.